Naar de inhoud
OneKitly

The Third Floor Costs More Pressure Than the Flow Does

Gepubliceerd op 28-10-2026 · 4 min leestijd · Dagelijkse calculators

Marco Bianchi

Marco Bianchi — Redacteur wonen, klussen en auto bij OneKitly

Verbouwen · Materialen

Getoetst aan 2 bronnen

Profiel bekijken →
Kort gezegd

Bernoulli's relation says pressure, speed and height trade against each other along a pipe, and the exchange rate is not what plumbing folklore suggests. Take mains water at 300 kPa (3 bar) moving at 1 m/s. Speed it up to 6 m/s at a tap and the pressure falls to 282.5 kPa — a loss of 17.5 kPa, under 6 %. Now raise the same water nine metres, three storeys, without changing its speed: the pressure falls from 3 bar to 2.12 bar, a loss of 88 kPa. Height costs five times more than flow. That is why the top floor of a building is where pressure complaints come from, and why a wider pipe fixes far less than people expect.

Advertentie

Speeding water from 1 to 6 m/s costs 17 kPa. Lifting it nine metres costs 88 kPa. Height beats velocity by five to one in domestic plumbing.

Why a wider pipe disappoints

Doubling a pipe's diameter quarters the water's speed for the same flow, which sounds decisive until you compute what it buys. Going from 6 m/s to 1.5 m/s recovers 16.8 kPa of the 17.5 kPa that speed was costing — nearly all of it, and still only a fifth of a bar. Against a nine-metre lift it is noise. The real reason wider pipes help in old buildings is different and lives outside this equation: friction against the pipe wall, which grows steeply as the bore narrows and as scale builds up inside it. Bernoulli describes the ideal exchange; friction is the separate tax, and in a corroded 15 mm run it is usually the larger of the two.

The rain butt trick

Open a tap at the bottom of a full container and the water leaves at a speed set by the depth alone, not by the container's width or the volume it holds. Two metres of head gives 6.26 m/s, whether the tank is a barrel or a swimming pool. That is the same equation with the pressure terms cancelling — atmosphere at the top, atmosphere at the jet — leaving height traded directly for speed. It also explains why the flow from a rain butt slows visibly as the level drops, and why raising the butt on blocks does more for a watering can than any change of tap. Every 10 cm of extra height is worth about a kilopascal, and the jet speed follows the square root.

Cost
What each change costs, from 300 kPa at 1 m/s
ChangePressure leftCost
Speed up to 3 m/s296.0 kPa4 kPa
Speed up to 6 m/s282.5 kPa17.5 kPa
Rise nine metres212 kPa88 kPa
Free jet from 2 m of head—6.26 m/s

Uitgewerkt met onze eigen calculator

Calculator wet van Bernoulli

Gegeven

Los op naar
Druk P₁
Dichtheid van de vloeistof (kg/m³)
998
Eenheid druk
Pa
P₁ (druk)
200
v₁ (m/s)
2
h₁ (m)
0
P₂ (druk)
180
v₂ (m/s)
0
h₂ (m)
0

Resultaat

Opgeloste waarde
-1.816

Deze cijfers komen uit de calculator hieronder, ze zijn niet met de hand ingetypt — ze worden opnieuw berekend telkens als de tool verandert.

Reken het door met je eigen cijfers →
Advertentie

Veelgestelde vragen

Does this explain why a shower weakens when a tap opens?
Partly, and the smaller part. Opening a second outlet raises the flow through the shared supply pipe, which does cost some pressure through the speed term — but as the figures show, that term is small. The dominant effect is friction: pressure loss along a pipe rises roughly with the square of the flow rate, so doubling the draw quadruples the loss in the shared section. The shower notices the friction in the pipe leading to the branch, not the speed in the branch itself. Fitting a thermostatic mixing valve treats the symptom by holding the ratio steady; enlarging the shared run treats the cause.
Where does the equation stop being valid?
Wherever energy leaves the fluid, which in practice is everywhere. The relation assumes no friction, no heat exchange, steady flow, and constant density along one streamline. Real pipes violate the first two continuously, pumps and valves inject or remove energy at a point, and any flow fast enough to become turbulent stops behaving like a single streamline at all. The equation remains useful as a budget: it tells you what the ideal exchange would be, and the shortfall between that and the measured pressure is the size of everything the model left out. Treating it as an exact prediction of tap pressure is how people conclude that physics is wrong about their bathroom.

Artikelen die je misschien interesseren

Alle gidsen →

Vergelijkbare tools

Bronnen

Een fout in dit artikel gezien?