The turns ratio of a transformer is the ratio of its voltages: 240 volts on the primary and 12 on the secondary is 20 to 1, meaning twenty turns of primary winding for every turn of secondary. Current runs the other way by the same factor, because the power crossing the core has to balance. A secondary delivering 5 amps at 12 volts is 60 watts, and the primary supplies that 60 watts at 240 volts by drawing only 0.25 amps. This is why the fuse on the mains side of a bench supply is so much smaller than the current the supply can deliver, and why a short circuit on a low-voltage secondary can look almost harmless on the primary side while melting something downstream.

Advertisement

240 V in, 12 V out is a ratio of 20. Voltage divides by 20 and current multiplies by 20, so 5 A on the secondary is 0.25 A on the primary — and 60 watts either way.

A transformer does nothing at all on direct current

The whole device works by a changing magnetic field inducing a voltage in the second winding, and a steady current produces a steady field, which induces nothing. Connect a mains transformer to a battery of the same voltage and the primary behaves as what it physically is — a long coil of thin wire with very little resistance — and draws whatever current the battery can supply until something gives. That is the practical reason a transformer belongs to alternating current and why direct-current systems need switching converters instead, which manufacture a changing field electronically before they can use the same trick.

The ideal balance is never quite reached

Sixty watts in and sixty watts out assumes a perfect transformer, and a real one loses a few per cent to resistance in the windings and to heating of the iron core. The losses in the core are there even with nothing connected, which is why an unloaded transformer left plugged in is warm and consuming power for no purpose. Efficiency also depends on load: a transformer running near its rating is usually at its best, while one delivering a tenth of what it was designed for wastes a much larger fraction of what it draws. Any figure calculated from the turns ratio alone is therefore a ceiling on what the secondary can deliver rather than a promise.

240 V to 12 V, ratio 20
SideVoltageCurrentPower
Primary240 V0.25 A60 W
Secondary12 V5 A60 W

Worked with our own calculator

Transformer turns ratio calculator

Given

Primary voltage (V)
240
Secondary voltage (V)
12

Result

Turns ratio (Np:Ns)
20

These figures are produced by the calculator below, not typed in by hand — they are recomputed whenever the tool changes.

Run it on your own figures →
Advertisement

Frequently asked questions

Can the same transformer be used backwards?
Electrically the physics is symmetric — feed 12 volts into the 12-volt winding and 240 appears on the other — but the construction is not. The low-voltage winding is wound with thick wire and little insulation because it was never meant to hold 240 volts, and the high-voltage side is thin wire that cannot carry the current a reversed connection would demand. Devices built for this, such as isolation transformers with equal windings, say so; anything else run backwards is being used outside what its insulation was designed for, and the failure mode is not a gentle one.
Why is high voltage used for transmission?
Because the loss in a cable depends on the current squared, and the transformer lets you choose the current. Sending a given power at twenty times the voltage means a twentieth of the current, and a twentieth of the current wastes a four-hundredth of the heat in the same conductor. That single ratio is why long-distance transmission runs at hundreds of thousands of volts and steps down repeatedly on the way to a house, and it is the reason the transformer is arguably the most consequential piece of nineteenth-century electrical engineering.

Articles you may find interesting

All guides →
ExplainerTen Amps Five Centimetres Away Rivals the Earth's Magnetic FieldA straight wire carrying 10 A produces 40 µT at 5 cm and 4 µT at 50 cm. Wind the same current into 1,000 turns per metre and it becomes 12,566 µT — three hundred times more.ExplainerA Coil That Is a Short Circuit at DC Is 628 Ohms at a Kilohertz100 mH presents 31.4 Ω at 50 Hz, 37.7 Ω at 60 Hz and 628.3 Ω at 1 kHz. The opposition is proportional to frequency and vanishes entirely at zero.ExplainerOne Time Constant Is 63 % of the Way, Not the End1,000 Ω with 100 µF gives a time constant of 0.1 s. The capacitor is 63 % charged at that point, 95 % after three constants and 99.3 % after five — the last of which is the number that matters.ExplainerA 5,000 mAh Power Bank Does Not Hold 5,000 mAh for Your Phone5,000 mAh drawn at 500 mA with 85 % efficiency runs for 8.5 hours instead of the arithmetic's 10. The same 15 % explains why a 5,000 mAh bank barely fills a 4,000 mAh phone once.ExplainerDouble the Current and the Cable Gets Four Times HotterPower lost as heat is current squared times resistance. Ten metres of 1.5 mm² extension lead has 0.233 Ω there and back: 23.3 W at 10 A, and 59.7 W at 16 A.ExplainerThe Voltage Divider: The Formula Is Trivial, the Assumption Behind It Is NotVout = Vin·R2/(R1+R2) is only true when nothing is connected to the output. Draw current and the voltage collapses, by an amount that follows one exact law. Here is that law, the ten-times rule checked against it, and why a lower-resistance divider costs you power forever.